WEB Catalog
Product Information »
WEB Catalog
IN_PROD_543
»
Electric Actuators/Cylinders
IN_PROD_628
»
Controllers/Drivers
Controller/Step Data Input Type LECP6/LECA6
![]() |
・The controller is already set with the data of the actuator.
(The actuator and controller are provided as a set.) ・Easy operation and simple setting: Easy mode, Detail setting: Normal mode ・Teaching box, controller setting software |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
Power consumption (W) |
Model | Flow characteristics 4/2 → 3/5 (A/B → E) C[dm3/(s・bar)] |
---|---|---|---|---|---|---|
Step data input type |
LECP6 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
11 (Photo-coupler isolation) |
13 (Photo-coupler isolation) |
64 points |
Step data input type |
LECA6 | Servo motor (24 VDC) |
24 VDC ±10% |
11 (Photo-coupler isolation) |
13 (Photo-coupler isolation) |
64 points |
Controller/Step Data Input TypeLECP6/LECA6
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Download |
---|---|---|
Step data input type |
LECP6 |
|
Step data input type |
LECA6 |
|
Step Motor Controller with Step Data Teaching Function
LECP6-XB120
LECP6-XB120
![]() |
・Neither a PC nor a teaching box is required
for adjusting the position of step data. ・With a JOG function for parallel input signals |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
Power consumption (W) |
Model | Flow characteristics 4/2 → 3/5 (A/B → E) C[dm3/(s・bar)] |
---|---|---|---|---|---|---|
Step data input type |
LECP6-XB120 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
11 (Photo-coupler isolation) |
13 (Photo-coupler isolation) |
64 points |
Step Motor Controller with Step Data Teaching Function<br>LECP6-XB120
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Download |
---|---|---|
Step data input type |
LECP6-XB120 |
|
Multi-Axis Step Motor Controller JXC73/83/92/93
![]() |
・Speed tuning control
・Linear/circular interpolation ・Positioning/pushing operation ・Absolute/relative position coordinate instructions ・Step data input (Max. 2048 points) ・Space saving, reduced wiring |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
Power consumption (W) |
Model |
---|---|---|---|---|---|
Step data input type |
JXC73 | NPN | Step motor (Servo/24 VDC) |
24 VDC ±10% |
Max. 4 axes |
Step data input type |
JXC83 | PNP | Step motor (Servo/24 VDC) |
24 VDC ±10% |
Max. 4 axes |
Step data input type |
JXC92 | EtherNet/IP™ | Step motor (Servo/24 VDC) |
24 VDC ±10% |
Max. 3 axes |
Step data input type |
JXC93 | EtherNet/IP™ | Step motor (Servo/24 VDC) |
24 VDC ±10% |
Max. 4 axes |
Multi-Axis Step Motor ControllerJXC73/83/92/93
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Download |
---|---|---|
Step data input type |
JXC73 |
|
Step data input type |
JXC83 |
|
Step data input type |
JXC92 |
|
Step data input type |
JXC93 |
|
For 4 Axes Simple Controller JXC□4-X1
![]() |
・2-point operation is possible without programming! (End to end)
・Reduced setting labor (Only the speed and force need to be set) ・Reduced wiring labor (Only 2 inputs/outputs*) *Per axis ・Space saving Footprint: Reduced by up to approx.79% |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
---|---|---|---|
JXC□4-X1 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
Max. 4 axes |
For 4 Axes Simple ControllerJXC□4-X1
Series | Download |
---|---|
JXC□4-X1 |
|
Programless Controller LECP1
![]() |
・No programming required
Capable of setting up an electric actuator operation without using a PC or teaching box ・Speed/acceleration 16-level adjustment ・Compatible with actuators with locks ・3-level pushing force settings |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
Power consumption (W) |
Model | Flow characteristics 4/2 → 3/5 (A/B → E) C[dm3/(s・bar)] |
---|---|---|---|---|---|---|
Programless type |
LECP1 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
6 (Photo-coupler isolation) |
6 (Photo-coupler isolation) |
14 points |
Programless ControllerLECP1
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Download |
---|---|---|
Programless type |
LECP1 |
|
With Input Signals to Perform Jog Operations Step Motor Controller LECP1-XB182
![]() |
・Jog operation can be performed using parallel input signals.
Jog operations that could previously only be performed using the button on the front face can now be performed using the ON/OFF status of the input signal. ・Application Examples Optimal for adjusting the feed value using a button operation while checking the motion of the actuator |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
Power consumption (W) |
Model | Flow characteristics 4/2 → 3/5 (A/B → E) C[dm3/(s・bar)] |
---|---|---|---|---|---|---|
With input signals to perform jogoperations |
LECP1-XB182 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
6 (Photo-coupler isolation) |
6 (Photo-coupler isolation) |
2 points |
With Input Signals to Perform Jog Operations Step Motor ControllerLECP1-XB182
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Download |
---|---|---|
With input signals to perform jogoperations |
LECP1-XB182 |
|
Programless Controller (With Stroke Study) LECP2
![]() |
・End to end operation similar to an air cylinder
・Positioning of 2 stroke end points + 12 intermediate points |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
Power consumption (W) |
Model | Flow characteristics 4/2 → 3/5 (A/B → E) C[dm3/(s・bar)] |
---|---|---|---|---|---|---|
Programless type (With stroke study) |
LECP2 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
6 (Photo-coupler isolation) |
6 (Photo-coupler isolation) |
2 stroke end points 12 intermediate points |
Programless Controller (With Stroke Study)LECP2
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Download |
---|---|---|
Programless type (With stroke study) |
LECP2 |
|
Step Motor Driver (Pulse Input Type) LECPA
![]() |
・A driver that uses pulse signals to allow positioning at any position
The actuator can be controlled from the customers' positioning unit. ・Return-to-origin command signal ・With force limit function (Pushing force/Gripping force operations are available.) |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
Power consumption (W) |
Model | Flow characteristics 4/2 → 3/5 (A/B → E) C[dm3/(s・bar)] |
---|---|---|---|---|---|---|
Pulse input type |
LECPA | Step motor (Servo/24 VDC) |
24 VDC ±10% |
5 (Photo-coupler isolation) |
9 (Photo-coupler isolation) |
― |
Step Motor Driver (Pulse Input Type)LECPA
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Download |
---|---|---|
Pulse input type |
LECPA |
|
Step Motor Controller/CC-Link Direct Input Type LECPMJ
![]() |
・CC-Link Ver. 1.10 compatible
・External data import function ・Position and speed can be monitored by the PLC touch panel (display). ・Step data can be edited from the PLC touch panel (display). |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
Power consumption (W) |
---|---|---|---|---|
CC-Link direct input type |
LECPMJ | Step motor (Servo/24 VDC) |
24 VDC ±10% |
CC-Link Ver.1.10 |
Step Motor Controller/CC-Link Direct Input TypeLECPMJ
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Download |
---|---|---|
CC-Link direct input type |
LECPMJ |
|
Step Motor Controller JXCE1/91/P1/D1/L1
![]() |
・EtherCAT™, EtherNet/IP™, PROFINET compatible, DeviceNet™
・Two types of operation command Step no. defining operation, Numerical data defining operation ・Transition wiring of communication cable ・Numerical monitoring available ・IO-Link communication can be performed. |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
---|---|---|---|
JXCE1 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
EtherCAT™ |
JXC91 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
EtherNet/IP™ |
JXCD1 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
DeviceNet™ |
JXCP1 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
PROFINET |
JXCL1 | Step motor (Servo/24 VDC) |
24 VDC ±10% |
IO-Link |
Step Motor ControllerJXCE1/91/P1/D1/L1
Series | Download |
---|---|
JXCE1 |
|
JXC91 |
|
JXCD1 |
|
JXCP1 |
|
JXCL1 |
|
Fieldbus-compatible Gateway (GW) Unit LEC-G
![]() |
・The LEm series electric actuators are applicable to Fieldbus protocols.
・Conversion unit for Fieldbus network and LEC serial communication ・2 methods of operation: Step data input, numerical data input ・Position, speed, and other. values can be checked on the PLC. |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
---|---|---|---|
LEC-G | CC-Link DeviceNet™ PROFIBUS DP EtherNet/IP™ |
24 VDC ±10% |
Series LECP6 Series LECA6 |
Fieldbus-compatible Gateway (GW) UnitLEC-G
Series | Download |
---|---|
LEC-G |
|
AC Servo Motor Driver (Pulse Input Type) LECS
![]() |
・Pulse input type motor driver
・Compatible motor capacity: 100 W, 200 W, 400 W ・Compatible encoders: Incremental type Absolute type ・Servo adjustment using auto gain tuning ・With display setting function ・Positioning by up to 255 point tables |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
Power consumption (W) |
Model |
---|---|---|---|---|---|
Pulse input type (For incremental encoder) |
LECSA | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
6 | 4 |
Pulse input type (For absolute encoder) |
LECSB | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
10 | 6 |
CC-Link direct input type (For absolute encoder |
LECSC | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
― | ― |
SSCNETⅢ/H type (For absolute encoder) |
LECSS-T | AC servo motor (100/200/400 W) |
200 to 240 VAC (50/60 Hz) |
― | ― |
Pulse Input Type/ Positioning Type (Absolute Type) |
LECSB-T | AC Servo Motor (100/200/400 W) |
200 to 240 VAC (50/60 Hz) |
10 | 6 |
CC-Link Direct Input Type (Absolute Type) |
LECSC-T | AC Servo Motor (100/200/400 W) |
200 to 230 VAC (50/60 Hz) |
― | ― |
SSCNETⅢ type (For absolute encoder) |
LECSS | AC servo motor (100/200/400 W) |
100 to 120 VAC (50/60 Hz) 200 to 230 VAC (50/60 Hz) |
― | ― |
AC Servo Motor Driver (Pulse Input Type)LECS
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Download |
---|---|---|
Pulse input type (For incremental encoder) |
LECSA |
|
Pulse input type (For absolute encoder) |
LECSB |
|
CC-Link direct input type (For absolute encoder |
LECSC |
|
SSCNETⅢ/H type (For absolute encoder) |
LECSS-T |
|
Pulse Input Type/ Positioning Type (Absolute Type) |
LECSB-T |
|
CC-Link Direct Input Type (Absolute Type) |
LECSC-T |
|
SSCNETⅢ type (For absolute encoder) |
LECSS |
|
AC Servo Motor Driver (MECHATROLINK Compatible) LECYM/LECYU
![]() |
・Position control, speed control, and torque control can be used.
・Control encoder: Absolute 20-bit encoder (Resolution: 1048576 p/rev) ・Applicable Fieldbus protocol: MECHATROLINK-2, MECHATROLINK-3 *Click here for the setup software |
Other Data |
---|
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Flow characteristics 4/2→3/5(A/B→E) b |
Applicable cylinder size |
Power consumption (W) |
Model |
---|---|---|---|---|---|
MECHATROLINK-Ⅱ type (For absolute encoder) |
LECYM | AC servo motor (100/200/400 W) |
200 to 230 VAC (50/60 Hz) |
7 (Number of optional allocations) |
1 (Number of fixed allocations) 3 (Number of optional allocations) |
MECHATROLINK-Ⅲ type (For absolute encoder) |
LECYU | AC servo motor (100/200/400 W) |
200 to 230 VAC (50/60 Hz) |
7 (Number of optional allocations) |
1 (Number of fixed allocations) 3 (Number of optional allocations) |
AC Servo Motor Driver (MECHATROLINK Compatible)LECYM/LECYU
Series | Flow characteristics 4/2→3/5(A/B→E) C[dm3/(s・bar)] |
Download |
---|---|---|
MECHATROLINK-Ⅱ type (For absolute encoder) |
LECYM |
|
MECHATROLINK-Ⅲ type (For absolute encoder) |
LECYU |
|